Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. bras. ciênc. vet ; 29(3): 125-129, jul./set. 2022. il.
Article in Spanish | LILACS, VETINDEX | ID: biblio-1411217

ABSTRACT

La medición de glucosa en caninos es un procedimiento habitual en la clínica diaria, actualmente este valor se puede obtener mediante dispositivos portátiles y pruebas laboratoriales. Se realizó esta investigación con el fin de aportar mayor conocimiento sobre la importancia de la medición de glucosa, ya que en los últimos años ha perdido valor entre las pruebas hematológicas a considerar debido a que solo se relaciona con determinadas patologías como la diabetes u otras enfermedades metabólicas. El presente trabajo tiene como objetivo comparar los valores de glucosa en caninos obtenidos mediante un glucómetro portátil de uso humano (Accu-chek® Active, Roche Diagnostic, Mannheim, Alemania); veterinario (aLcose® Vet Glu, jjPlus Corporation, New Taipei, Taiwán) y la prueba estándar de laboratorio, esto nos indicará la fiabilidad de los resultados obtenidos mediante estos métodos. Se realizó la toma de muestras de sangre de 50 caninos clínicamente sanos, de los cuales se obtuvo el resultado de glucemia mediante estos tres métodos. Los resultados de nuestra investigación evidenciaron que las tres formas de evaluación de la glucosa sanguínea en perros brindaban resultados estadísticamente diferentes (p < 0.05). Se obtuvo valores de glucosa diferentes entre los tres métodos de medición, teniendo como promedios finales 84.14 mg/dL, 101.12 mg/dL y 91.12 mg/dL correspondientes al glucómetro portátil de uso humano, veterinario y a la prueba estándar de laboratorio respectivamente. En conclusión, los glucómetros portátiles de uso humano subestiman los valores reales de glucosa, mientras que los de uso veterinario lo sobreestiman, comparados con la prueba estándar de laboratorio.


A medição de glicose nos cães é um procedimento habitual realizado no atendimento clínico. Atualmente este valor pode ser obtido por meio de dispositivos portáteis e testes laboratoriais. Esta pesquisa foi realizada com a finalidade de destacar a importância da medição de glicose, visto que nos últimos anos esta avaliação não tem sido muito valorada entre os testes hematológicos, sendo considerada relevante apenas em relação a patologias como a diabetes e outras doenças metabólicas. O presente estudo teve como objetivo comparar os valores de glicose em cães obtidos com glicômetro portátil de uso humano; veterinário e o teste padrão de laboratório. Esta comparação poderá indicar a confiabilidade dos resultados obtidos mediante os métodos avaliados. Foi realizada a amostragem do sangue de 50 caninos clinicamente sadios os quais foram submetidos a avaliação de glicose mediante os três métodos. Os resultados de nossa investigação evidenciaram que as três formas de avaliação da glicose sanguínea têm resultados estatisticamente diferentes (p < 0,05). Os valores de glicose tiveram medias finais de 84,14 mg/dL, 101,12 mg/dL e 91,12 mg/dL para o glicômetro portátil de uso humano (Accu-chek® Active, Roche Diagnostic, Mannheim, Alemanha), veterinário (aLcose® Vet Glu, jjPlus Corporation, Nova Taipei, Taiwan) e o teste padrão de laboratório, respectivamente. Ao concluir, os glicômetros portáteis de uso humano subestimam os valores reais de glicose e os de uso veterinário os superestimam quando comparados com o teste padrão de laboratório.


The measurement of glucose in canines is a common procedure in daily clinical practice. Currently this value can be obtained by use of portable devices and laboratory tests. This research was carried out in order to provide more knowledge about the importance of glucose measurement, since in recent years it has lost value among the hematological tests to be considered because it is only related to certain pathologies such as diabetes or other metabolic diseases. The present study aimed to compare the glucose values in dogs obtained with a portable glucometer for human use, veterinarian use, and the standard laboratory test. This comparison may indicate the reliability of the results obtained through the evaluated methods. A blood sampling of 50 clinically healthy canines was taken and submitted to glucose evaluation using the three methods. Our investigation showed that the three ways of assessing blood glucose have statistically different results (p < 0.05). Glucose values had final averages of 84.14 mg/dL, 101.12 mg/dL, and 91.12 mg/dL for the portable glucometer for human use (Accu-chek® Active, Roche Diagnostic, Mannheim, Germany), veterinary (aLcose® Vet Glu, jjPlus Corporation, New Taipei, Taiwan) and the standard laboratory test, respectively. In conclusion, portable glucometers for human use underestimate the glucose values, and those for veterinary use overestimate them compared to the standard laboratory test.


Subject(s)
Animals , Dogs , Blood Chemical Analysis/veterinary , Blood Glucose/analysis , Blood Glucose Self-Monitoring/veterinary , Dogs/blood , Glucose/analysis , Glucose Tolerance Test/veterinary
2.
Arq. Inst. Biol ; 82: 1-9, 2015. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1025970

ABSTRACT

Nitrofurans are antibacterials banned in livestock by different countries due to its relationship with the production of carcinogenic metabolites. Several studies have been conducted to find the best methodology to identify these residues. Te objectives of this review work were to show the risk of nitrofuran metabolites (furazolidone; nitrofurazone; nitrofurantoin, furaltadone and nifursol); to explain the application of liquid chromatography and mass spectrometry to determine the presence of these residues in foods of animal origin; and, finally, to report some methodologies that were recently used in different foods of animal origin.(AU)


Nitrofuranos são antibacterianos proibidos na criação de animais por diferentes países devido a sua relação com a produção de metabolitos carcinogênicos. Vários trabalhos de pesquisa têm sido desenvolvidos para encontrar a melhor metodologia que possa identificar esses resíduos. O presente trabalho de revisão teve como objetivos mostrar o risco dos metabolitos dos nitrofuranos (furazolidona, nitrofurazona, nitrofurantoina, furaltadona e nifursol); explicar a aplicação da cromatografia líquida e da espectrometria de massas para determinar a presença desses resíduos em alimentos de origem animal; e, finalmente, relatar algumas metodologias usadas recentemente em alimentos de origem animal.(AU)


Subject(s)
Drug Residues/analysis , Foods of Animal Origin , Anti-Bacterial Agents , Nitrofurans , Mass Spectrometry , Food Inspection , Chromatography, Liquid
SELECTION OF CITATIONS
SEARCH DETAIL